Default Re: A synthesis question about "high-fanout nets"

Execuse me for one more question.

I have tried but the result surprised me.
The high fan-out net I have been searched for these days are *Logic0*.

I am not sure if this is normal.

Or maybe something wrong , say coding style bugs?

And most of all, should I care about *Logic0*?



[email protected] (Alexander Gnusin) wrote in message news:<[email protected] com>...
> [email protected] (walter) wrote in message news:<[email protected] com>...
> > Hi All,
> >
> > I am not sure if this is the right place to post the title. But I will
> > be very appreciated if any one can help.
> >
> > When synthesis with Synopsys Design Compiler, I got the message :
> >
> > Warning: Design 'ooo' contains 1 high-fanout nets. A fanout number of
> > 1000 will be used for delay calculations involving these nets.
> > (TIM-134)
> >
> > 1. Is the warning quite important?

>
> DC uses the following formula to calculate net capacitance:
> NET CAP = SUM OF ALL Cpins + Wire Cap, where:
> Cpin is input capacitance of each driven pin;
> Wire Cap is net capacitance, which is calculated from WLM using net
> fanout and design area info. During Design optimization, DC need to
> recalc NET CAP value capacitance every time it adds / removes net
> loads.
>
> However, for high fanout nets different formula is used:
> NET CAP = high_fanout_net_threshold * high_fanout_net_pin_capacitance
> + Wire Cap
> where high_fanout_net_threshold and high_fanout_net_pin_capacitance
> are two initially predefined DC variables.
> So, if net fanout exceeds high_fanout_net_threshold , NET CAP becomes
> fixed and will not be recalculated every time DC makes incremental
> changes.
>
>
>
> > 2. How can I identify the high-fanout nets?

> You may run "report_net_fanout -high_fanout" command (see help for
> command options)
>
>
> > 3. How can I fix the warning?

> Use set_ideal_net or set_ideal_network commands to exclude net from
> any optimizations.
>
> > I guess it might be reset or clock signal.
> > So I use
> > set_drive 0
> > set_dont_touch_network
> > on all clocks and reset
> > But still got the warning.

>
> Regards,
> Alexander Gnusin
> www.TCLforEDA.net

Reply With Quote