  #1 (permalink)  
Old 11-29-2004, 08:00 AM
Falk Salewski
Guest
 
Posts: n/a
Default CPLD + CAN bus

Hello everybody,

I want to connect a Xilinx CoolrunnerII (XC2c256) to the CAN-Bus. To make it
easy I would like to use a ready to use CAN-bus driver chip (as much of the
protocol implemented as possible). Any suggestions? How many of the CPLD
resources does it take to initialize/communicate with the CAN-bus driver
chip?

Thanks for your help!

Falk Salewski
Embedded Software Laboratory
RWTH Aachen University
-----------------------------------------------------------------------


Reply With Quote
  #2 (permalink)  
Old 11-29-2004, 08:50 AM
Uwe Bonnes
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Falk Salewski <salewski@informatik.rwth-aachen.de> wrote:
: Hello everybody,

: I want to connect a Xilinx CoolrunnerII (XC2c256) to the CAN-Bus. To make
: it easy I would like to use a ready to use CAN-bus driver chip (as much of
: the
: protocol implemented as possible). Any suggestions? How many of the CPLD
: resources does it take to initialize/communicate with the CAN-bus driver
: chip?

There is a CAN Protocoll Controller at www.opencores.org

Bye
--
Uwe Bonnes bon@elektron.ikp.physik.tu-darmstadt.de

Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt
--------- Tel. 06151 162516 -------- Fax. 06151 164321 ----------
Reply With Quote
  #3 (permalink)  
Old 11-29-2004, 09:36 AM
Falk Salewski
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Thank you very much for your reply.

However what I am looking for is how difficult is it to connect a CPLD to a
CAN-controller chip like the SJA1000
http://www-eu3.semiconductors.com/pip/SJA1000.html
and how many of the CPLD resources it takes to initialize/communicate with
this CAN-controller.

bye
Falk

"Uwe Bonnes" <bon@elektron.ikp.physik.tu-darmstadt.de> schrieb im
Newsbeitrag news:coensd$mh6$1@lnx107.hrz.tu-darmstadt.de...
> Falk Salewski <salewski@informatik.rwth-aachen.de> wrote:
> : Hello everybody,
>
> : I want to connect a Xilinx CoolrunnerII (XC2c256) to the CAN-Bus. To
> make
> : it easy I would like to use a ready to use CAN-bus driver chip (as much
> of
> : the
> : protocol implemented as possible). Any suggestions? How many of the CPLD
> : resources does it take to initialize/communicate with the CAN-bus driver
> : chip?
>
> There is a CAN Protocoll Controller at www.opencores.org
>
> Bye
> --
> Uwe Bonnes bon@elektron.ikp.physik.tu-darmstadt.de
>
> Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt
> --------- Tel. 06151 162516 -------- Fax. 06151 164321 ----------



Reply With Quote
  #4 (permalink)  
Old 11-29-2004, 10:11 AM
Jim Granville
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Falk Salewski wrote:
> Thank you very much for your reply.
>
> However what I am looking for is how difficult is it to connect a CPLD to a
> CAN-controller chip like the SJA1000
> http://www-eu3.semiconductors.com/pip/SJA1000.html
> and how many of the CPLD resources it takes to initialize/communicate with
> this CAN-controller.


You'll need to setup the registers [either a rom in the CPLD, or
a Serial EE holding the init values, to BUS], and then be able to poll
messages, and manage TX packets (which come from where ?).

All of these are not CPLD-centric tasks, so why not use a small uC
instead - or even better, choose a uC with CAN on chip ?
If you have the XC2C256 there already, needing > 128 MC for other
tasks, then you could use a small portion, for SPI-SJA1000 bridge, and
then use a small SPI uC for the CAN manager/init.
Philips LPC9xx or Silicon Labs C8051F33x series would do this, in tiny
11-20pin packages.
-jg


Reply With Quote
  #5 (permalink)  
Old 11-29-2004, 10:16 AM
Uwe Bonnes
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Falk Salewski <salewski@informatik.rwth-aachen.de> wrote:
: Thank you very much for your reply.

: However what I am looking for is how difficult is it to connect a CPLD to a
: CAN-controller chip like the SJA1000
: http://www-eu3.semiconductors.com/pip/SJA1000.html
: and how many of the CPLD resources it takes to initialize/communicate
: with this CAN-controller.

: bye
: Falk

: "Uwe Bonnes" <bon@elektron.ikp.physik.tu-darmstadt.de> schrieb im
: Newsbeitrag news:coensd$mh6$1@lnx107.hrz.tu-darmstadt.de...
: > Falk Salewski <salewski@informatik.rwth-aachen.de> wrote:
....

Can communication needs some protocoll stack. Your question seems to be what
implementing this stack in hardware needs with regards to hardware
resources.

My guess is that the 2c256 is too small for that task.

Bye
--
Uwe Bonnes bon@elektron.ikp.physik.tu-darmstadt.de

Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt
--------- Tel. 06151 162516 -------- Fax. 06151 164321 ----------
Reply With Quote
  #6 (permalink)  
Old 11-29-2004, 11:01 AM
Uwe Bonnes
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Jim Granville <no.spam@designtools.co.nz> wrote:

: All of these are not CPLD-centric tasks, so why not use a small uC
: instead - or even better, choose a uC with CAN on chip ?
: If you have the XC2C256 there already, needing > 128 MC for other
: tasks, then you could use a small portion, for SPI-SJA1000 bridge, and
: then use a small SPI uC for the CAN manager/init.
: Philips LPC9xx or Silicon Labs C8051F33x series would do this, in tiny
: 11-20pin packages.

Perhaps PicoBlaze for CoolRunner-II could be used too...

Bye

--
Uwe Bonnes bon@elektron.ikp.physik.tu-darmstadt.de

Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt
--------- Tel. 06151 162516 -------- Fax. 06151 164321 ----------
Reply With Quote
  #7 (permalink)  
Old 11-29-2004, 12:21 PM
Falk Salewski
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Thanks for the reply!

I realized four 8bit counters in the CPLD and just want to send this
information (4Byte) via the CAN-Bus, lets say all 100ms. Right know I am not
thinking wether this is the optimal solution but if it is possible without
an aditional uC (Project at university)
I will have a look if I can store enough information in the CPLD for the
initialization of the SJA1000 chip...

FalkS.

"Jim Granville" <no.spam@designtools.co.nz> schrieb im Newsbeitrag
news:mBCqd.13010$3U4.254093@news02.tsnz.net...
> Falk Salewski wrote:
>> Thank you very much for your reply.
>>
>> However what I am looking for is how difficult is it to connect a CPLD to
>> a CAN-controller chip like the SJA1000
>> http://www-eu3.semiconductors.com/pip/SJA1000.html
>> and how many of the CPLD resources it takes to initialize/communicate
>> with this CAN-controller.

>
> You'll need to setup the registers [either a rom in the CPLD, or
> a Serial EE holding the init values, to BUS], and then be able to poll
> messages, and manage TX packets (which come from where ?).
>
> All of these are not CPLD-centric tasks, so why not use a small uC
> instead - or even better, choose a uC with CAN on chip ?
> If you have the XC2C256 there already, needing > 128 MC for other tasks,
> then you could use a small portion, for SPI-SJA1000 bridge, and then use a
> small SPI uC for the CAN manager/init.
> Philips LPC9xx or Silicon Labs C8051F33x series would do this, in tiny
> 11-20pin packages.
> -jg
>
>



Reply With Quote
  #8 (permalink)  
Old 11-29-2004, 12:23 PM
Falk Salewski
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus


"Uwe Bonnes" <bon@elektron.ikp.physik.tu-darmstadt.de> schrieb im
Newsbeitrag news:coest7$o8j$1@lnx107.hrz.tu-darmstadt.de...
> Falk Salewski <salewski@informatik.rwth-aachen.de> wrote:
> : Thank you very much for your reply.
>
> : However what I am looking for is how difficult is it to connect a CPLD
> to a
> : CAN-controller chip like the SJA1000
> : http://www-eu3.semiconductors.com/pip/SJA1000.html
> : and how many of the CPLD resources it takes to initialize/communicate
> : with this CAN-controller.
>
> : bye
> : Falk
>
> : "Uwe Bonnes" <bon@elektron.ikp.physik.tu-darmstadt.de> schrieb im
> : Newsbeitrag news:coensd$mh6$1@lnx107.hrz.tu-darmstadt.de...
> : > Falk Salewski <salewski@informatik.rwth-aachen.de> wrote:
> ...
>
> Can communication needs some protocoll stack. Your question seems to be
> what
> implementing this stack in hardware needs with regards to hardware
> resources.
>
> My guess is that the 2c256 is too small for that task.
>
> Bye
> --
> Uwe Bonnes bon@elektron.ikp.physik.tu-darmstadt.de
>
> Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt
> --------- Tel. 06151 162516 -------- Fax. 06151 164321 ----------


I thought the protocoll stack is already implemented in the SJA1000 and I
just have to write to some kind of send buffer and read from a receive
buffer...

Falk


Reply With Quote
  #9 (permalink)  
Old 11-29-2004, 12:43 PM
Antti Lukats
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus


"Falk Salewski" <salewski@informatik.rwth-aachen.de> wrote in message
news:310ihvF31ii5hU1@uni-berlin.de...
> Thanks for the reply!
>
> I realized four 8bit counters in the CPLD and just want to send this
> information (4Byte) via the CAN-Bus, lets say all 100ms. Right know I am

not
> thinking wether this is the optimal solution but if it is possible without
> an aditional uC (Project at university)
> I will have a look if I can store enough information in the CPLD for the
> initialization of the SJA1000 chip...


http://ww1.microchip.com/downloads/e...Doc/21801b.pdf

Quiz: How many macrocells is needed to initialize MMC card (nonSPI mode) and
configure and FPGA from bitstream file on the card?

Answer: 20 PLD macrocells!

http://www.openchip.org/bootx/xmsmmc.html

256 PLD cells can be alot. depends how they are used

but I would not go with SJA1000+PLD (unless restricted to those component by
definition) waste of time and human resources

Antti


Reply With Quote
  #10 (permalink)  
Old 11-29-2004, 02:08 PM
Aurelian Lazarut
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Hi Antti,

Antti Lukats wrote:

>"Falk Salewski" <salewski@informatik.rwth-aachen.de> wrote in message
>news:310ihvF31ii5hU1@uni-berlin.de...
>
>
>>Thanks for the reply!
>>
>>I realized four 8bit counters in the CPLD and just want to send this
>>information (4Byte) via the CAN-Bus, lets say all 100ms. Right know I am
>>
>>

>not
>
>
>>thinking wether this is the optimal solution but if it is possible without
>>an aditional uC (Project at university)
>>I will have a look if I can store enough information in the CPLD for the
>>initialization of the SJA1000 chip...
>>
>>

>
>http://ww1.microchip.com/downloads/e...Doc/21801b.pdf
>
>Quiz: How many macrocells is needed to initialize MMC card (nonSPI mode) and
>configure and FPGA from bitstream file on the card?
>
>Answer: 20 PLD macrocells!
>
>http://www.openchip.org/bootx/xmsmmc.html
>
>

No file system support (I assume) and no partition support. How do you
write the bitstream as row data ?
cheers,
Aurash

>256 PLD cells can be alot. depends how they are used
>
>but I would not go with SJA1000+PLD (unless restricted to those component by
>definition) waste of time and human resources
>
>Antti
>
>
>
>



--
__
/


Reply With Quote
  #11 (permalink)  
Old 11-29-2004, 02:54 PM
Antti Lukats
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

"Aurelian Lazarut" <aurash@xilinx.com> wrote in message
news:cofagb$m5k1@cliff.xsj.xilinx.com...
> Hi Antti,
>
> Antti Lukats wrote:
>
> >"Falk Salewski" <salewski@informatik.rwth-aachen.de> wrote in message
> >news:310ihvF31ii5hU1@uni-berlin.de...
> >
> >
> >>Thanks for the reply!
> >>
> >>I realized four 8bit counters in the CPLD and just want to send this
> >>information (4Byte) via the CAN-Bus, lets say all 100ms. Right know I am
> >>
> >>

> >not
> >
> >
> >>thinking wether this is the optimal solution but if it is possible

without
> >>an aditional uC (Project at university)
> >>I will have a look if I can store enough information in the CPLD for the
> >>initialization of the SJA1000 chip...
> >>
> >>

> >
> >http://ww1.microchip.com/downloads/e...Doc/21801b.pdf
> >
> >Quiz: How many macrocells is needed to initialize MMC card (nonSPI mode)

and
> >configure and FPGA from bitstream file on the card?
> >
> >Answer: 20 PLD macrocells!
> >
> >http://www.openchip.org/bootx/xmsmmc.html
> >
> >

> No file system support (I assume) and no partition support. How do you
> write the bitstream as row data ?
> cheers,
> Aurash


KISS

format the MMC card, then copy download.bit to the card! thats it. simple as
that.
if once written can be overwritten without the need to format the card.

Of course I do have some utilities to write directly to the card (in hidden
area) too, but those arent even necessary

Antti








Reply With Quote
  #12 (permalink)  
Old 11-29-2004, 07:02 PM
Jim Granville
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Falk Salewski wrote:
> Thanks for the reply!
>
> I realized four 8bit counters in the CPLD and just want to send this
> information (4Byte) via the CAN-Bus, lets say all 100ms. Right know I am not
> thinking wether this is the optimal solution but if it is possible without
> an aditional uC (Project at university)
> I will have a look if I can store enough information in the CPLD for the
> initialization of the SJA1000 chip...


First, find some working SJA1000 software, in any uC family will do.
Search also for the 82C200, which is the older sibling
of the SJA1000. Philips will probably have some 80C51 examples.
Then, look to move that function into the CPLD.
To give your tutor some real numbers, assemble JUST the code for
init & simple Echo, and print the LINK MAP, to show how much RAM and
CODE space is needed. [eg it might be 5 bytes of RAM, and 275 Bytes of Code]

I think I saw recently a CAN controller [SJA1000 like], that could
as an option, 'wake up' in simple peripheral mode, IIRC using a Serial
EE to config. That would be another 'no code' alternative.

-jg

>
> FalkS.
>
> "Jim Granville" <no.spam@designtools.co.nz> schrieb im Newsbeitrag
> news:mBCqd.13010$3U4.254093@news02.tsnz.net...
>
>>Falk Salewski wrote:
>>
>>>Thank you very much for your reply.
>>>
>>>However what I am looking for is how difficult is it to connect a CPLD to
>>>a CAN-controller chip like the SJA1000
>>>http://www-eu3.semiconductors.com/pip/SJA1000.html
>>>and how many of the CPLD resources it takes to initialize/communicate
>>>with this CAN-controller.

>>
>> You'll need to setup the registers [either a rom in the CPLD, or
>>a Serial EE holding the init values, to BUS], and then be able to poll
>>messages, and manage TX packets (which come from where ?).
>>
>> All of these are not CPLD-centric tasks, so why not use a small uC
>>instead - or even better, choose a uC with CAN on chip ?
>> If you have the XC2C256 there already, needing > 128 MC for other tasks,
>>then you could use a small portion, for SPI-SJA1000 bridge, and then use a
>>small SPI uC for the CAN manager/init.
>> Philips LPC9xx or Silicon Labs C8051F33x series would do this, in tiny
>>11-20pin packages.
>> -jg
>>
>>

>
>
>


Reply With Quote
  #13 (permalink)  
Old 11-29-2004, 07:22 PM
Falk Brunner
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus


"Falk Salewski" <salewski@informatik.rwth-aachen.de> schrieb im Newsbeitrag
news:31038aF32l671U1@uni-berlin.de...
> Hello everybody,
>
> I want to connect a Xilinx CoolrunnerII (XC2c256) to the CAN-Bus. To make

it
> easy I would like to use a ready to use CAN-bus driver chip (as much of

the
> protocol implemented as possible). Any suggestions? How many of the CPLD


If you do so, use a uC with integrated CAN controller. But then you dont
need a CPLD anymore.
I dont see the point of using a CPLD with CAN. You CAN do it ;-) of cource.

Regards
Falk



Reply With Quote
  #14 (permalink)  
Old 11-29-2004, 07:24 PM
Falk Brunner
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus


"Falk Salewski" <salewski@informatik.rwth-aachen.de> schrieb im Newsbeitrag
news:310ihvF31ii5hU1@uni-berlin.de...
> Thanks for the reply!
>
> I realized four 8bit counters in the CPLD and just want to send this
> information (4Byte) via the CAN-Bus, lets say all 100ms. Right know I am

not
> thinking wether this is the optimal solution but if it is possible without
> an aditional uC (Project at university)


It CAN be doen this way, but

-- it is more expensive.
-- more complicated

Regards
Falk


Reply With Quote
  #15 (permalink)  
Old 11-29-2004, 07:25 PM
Falk Brunner
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus


"Antti Lukats" <antti@case2000.com> schrieb im Newsbeitrag
news:cofco1$b9n$05$1@news.t-online.com...

> KISS
>
> format the MMC card, then copy download.bit to the card! thats it. simple

as
> that.
> if once written can be overwritten without the need to format the card.


Nice trick, but Iam afraid the CAN bus protocoll is a LITTLE bit more
complex.

Regards
Falk



Reply With Quote
  #16 (permalink)  
Old 11-29-2004, 08:08 PM
Antti Lukats
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus


"Falk Brunner" <Falk.Brunner@gmx.de> wrote in message
news:311ckvF309jd8U8@uni-berlin.de...
>
> "Antti Lukats" <antti@case2000.com> schrieb im Newsbeitrag
> news:cofco1$b9n$05$1@news.t-online.com...
>
> > KISS
> >
> > format the MMC card, then copy download.bit to the card! thats it.

simple
> as
> > that.
> > if once written can be overwritten without the need to format the card.

>
> Nice trick, but Iam afraid the CAN bus protocoll is a LITTLE bit more
> complex.
>
> Regards
> Falk


LOL, yes just a little

well only wanted to point out that 256 cells PLDs SHOULD be large enough for
register init sequencer to initialize some CAN interface chip like MCP2515

antti


Reply With Quote
  #17 (permalink)  
Old 11-29-2004, 08:41 PM
Jim Granville
Guest
 
Posts: n/a
Default Re: CPLD + CAN bus

Falk Salewski wrote:
> Thanks for the reply!
>
> I realized four 8bit counters in the CPLD and just want to send this
> information (4Byte) via the CAN-Bus, lets say all 100ms. Right know I am not
> thinking wether this is the optimal solution but if it is possible without
> an aditional uC (Project at university)
> I will have a look if I can store enough information in the CPLD for the
> initialization of the SJA1000 chip...


If you change the SJA1000, to the Microchip MCP25020, that
has 8 I/O and on chip config registers so can 'wake up alive'.

Simplest scheme to tranfer counter info, from a CPLD, would be
a nibble-ram map, where you allocate 4 of the I/O as Address, and
4io as read-back nibble.
A Write-Read CAN transaction, then Sends Address, and recovers one
firmly identified nibble, and 16 nibbles can map 8 bytes of info.

-jg

Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
PLL in CPLD Kriki FPGA 1 09-17-2004 08:15 AM
CPLD : Is there a way Lolotheguru FPGA 1 09-05-2004 10:44 AM
GAL,PAL,PLD, CPLD,FPGA FPGA 7 08-21-2004 03:14 AM
fpga vs. cpld Rajeev FPGA 0 07-30-2004 12:43 AM
cpld's in a DIL package available MikeJ FPGA 0 09-09-2003 10:33 PM


All times are GMT +1. The time now is 08:12 AM.


Powered by vBulletin® Version 3.8.0
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.2.0
Copyright 2008 @ FPGA Central. All rights reserved